All sizes are complete with double circuit, by-pass line and double containment tank under the base in an emergency to ensure maximum and total reliability in case of breakdown or damage due to improper use. Each system has these backup systems:
Article 107 discharges into sewer networks c.1 of the same decree, establishes that the discharges of industrial waste water that deliver to sewer networks are subject to the technical standards, prescriptions and regulations and to the limit values ??adopted by the competent authority based on the characteristics of the system and in such a way that the protection of the receiving water body is ensured.
The Regions, in the exercise of their autonomy, in implementing the water protection plans, taking into account the maximum permissible loads, the best available techniques, define the emission limit values ??that the discharges concerned must not exceed.
Since reagents are used in the analysis process carried out in the Laboratory, it follows that concentrated discharges must certainly be treated as waste. As for the diluted discharges which are made up of waste liquids, deriving from the washing water used for the cuvettes, mixers, etc., it is necessary to check the level of concentration to evaluate their impact.
The treatment cycle is guaranteed by a first collection section called mixing complete with pump and sterilizer.
A second section by means of suitable filters controlled on the hours of operation and / or pressure losses ensures the treatment of effluents from clinical chemistry analyzers for discharge into the sewer.
MODULE A+B | FILTER NUMBER | DIMENSIONS | DRY WEIGHT | WEIGHT IN OPERATION | MAXIMUM FLOW | SPECIFICATIONS VALID FOR EVERY SIZE |
---|---|---|---|---|---|---|
A+2B | 2x2 | 1000x500x1370 | 330 Kg | 420Kg | 300l/h | Installed power 1000VA |
A+4B | 4x2 | 1000x500x1370 | 510 Kg | 680 Kg | 300l/h | Installed power 500VA |
A+6B | 6x2 | 1000x500x1370 | 940 Kg | 940 Kg | 300l/h | Power supply voltage: 220V/240V, 50hZ/60Hz |
WATER SUPPLY* | AVERAGE DAILY SANITARY WATER CONSUMPTION 200 L |
---|---|
minimum pressure | 3 bar |
maximum pressure | 4 bar |
minumim temperature | 6 C |
maximum temperature | 38 C |
EXHAUST HEIGHT | Maximum height of the drain floor 120 cm |
---|---|
CARATHERICSTICS OF THE CONNECTION |
All hydraulic inlets and drains are by means of a quick coupling for 22mm external diameter pipe |
NOIZE AND VIBRATION |
The machine is extremely silent, and in normal operating conditions it is not a source of vibrations |
DISSIPATION ON THE ENVIRONMENT |
In the surrounding air dissipation of 40W in continuous form. In treated water 500W only for the treated discharge time |
UMIDITY AND TEMPERATURE | From 5 ° to 35 ° relative humidity 85% without condensation |