The control module A and a filtering module B. The system can therefore be considered modular on the basis of specific needs.
The control module A and a filtering module B. The system can therefore be considered modular on the basis of specific needs.
All sizes are complete with double circuit, by-pass line and containment tank under the base in emergency to ensure maximum and total reliability in case of failure or damage due to improper use.
The machine includes an emulsion phase, a UV disinfection phase, a filtering phase and a finishing phase of the effluent, consisting of the passage through an ultraviolet lamp to reduce any residual charge. In the event of a malfunction, the system automatically goes into bypass, sending the wastewater to the collection system in use at the Laboratory.
The machine has an internal modem system equipped with an M2M data transmission card.
The management software also allows you to record, store and archive the operating parameters over time with consequent pre-management / prediction of any malfunctions. The main alarms are also visible on the control module A screen. The operator is therefore able to monitor the instrumental status in real time. The optical and acoustic system will allow the operator to notice that the system is in alarm even if it is not near it.
The installation operation is extremely quick, by means of flexible pipes with quick couplings, it can be easily connected to the machines and to the local unloading point. All the electrical / electronic components will be assembled and acquired with CE certification by leading manufacturers.
The treatment cycle is guaranteed by a first collection section called mixing complete with pump and UV sterilizer
MODULE A+B | DIMENSIONS | WEIGHT IN OPERATION | MAXIMUM CAPACITY (max. contemporaneity) | SPECIFICATIONS VALID FOR EVERY SIZE |
---|---|---|---|---|
A+2B | 1000x500x1370 | 420Kg | 200l/h | Installed power 1000VA |
A+4B | 1000x500x1370 | 680 Kg | 200l/h | Power in operation 500VA |
A+6B | 1000x500x1370 | 940 Kg | 200l/h | Power supply voltage: 220V/240V, 50hZ/60Hz |
WATER SUPPLY* | AVERAGE DAILY SANITARY WATER CONSUMPTION 200 l |
---|---|
Minimum pressure | 3 bar |
Maximum pressure | 4 bar |
Minimum temperature | 6 C |
Maximum temperature | 38 C |
EXHAUST HEIGHT | Maximum height of the drain floor 120 cm |
---|---|
CHARACTERISTICS OF THE CONNECTIONS |
All the hydraulic inlets and outlets are by means of a quick coupling for 22mm external diameter pipe |
VIBRATION AND NOISE |
The machine is extremely silent, and in normal operating conditions it is not a source of vibrations |
ENVIRONMENTAL DISSIPATION | In the surrounding air, dissipation of 40W in a continuous form. In treated water 500W only for the treated discharge time |
TEMPERATURE AND HUMIDITY |
From 5 ° to 35 ° relative humidity 85% without condensation |